LS108 Spectrum Transmission Meter
Product Details:
- Usage Test Purple light peak wavelength 395nm, Blue light peak wavelength 430nm transmittance and 380-760nm visible light transmittance
- Size 170x180x144mm
- Material aluminum alloy
- Power Supply DC5V/1A
- Height 144 Millimeter (mm)
- Product Type Spectrum Transmission Meter
- Power Consumption 5 Volt (V)
- Click to View more
LS108 Spectrum Transmission Meter Price And Quantity
- 450.00 - 480.00 USD ($)/Set
- 2 Unit
LS108 Spectrum Transmission Meter Product Specifications
- 1570 Grams (g)
- 180 Millimeter (mm)
- Test Purple light peak wavelength 395nm, Blue light peak wavelength 430nm transmittance and 380-760nm visible light transmittance
- ±2 %
- aluminum alloy
- 5 Volt (V)
- 170x180x144mm
- DC5V/1A
- Spectrum Transmission Meter
- White
- Digital Only
- 170 Millimeter (mm)
- 144 Millimeter (mm)
LS108 Spectrum Transmission Meter Trade Information
- Hong Kong
- 1000 Unit Per Month
- 10 Days
- Contact us for information regarding our sample policy
- LS108 Spectrum Transmission Meter*1 DC5V Adapter*1 User Manual*1 Certificate / warranty card*1 Packing box dimension 231*241*161 cm(L*W*H)*1
- Australia, Central America, Eastern Europe, Western Europe, Middle East, South America, Asia, North America, Africa
- All India
Product Description
The meter is widely applicable
The spectrum transmission meter has a wide range of applications, suitable for the transmission and rejection rate test of glasses, glass, anti-blue light materials, mobile phone lenses, etc
Measure multiple sets of data at once
The light transmission meter can simultaneously measure the transmission value and rejection rate of 430nm blue light /395nm purple light /380nm-760nm visible light and UV400 (the maximum ultraviolet rejection wavelength)
Three-in-one light source path
The meter uses one light path. Three transmission values can be obtained by measuring one time
Testing of UV400 is available
The UV400 is an important parameter used to judge the UV protection ability of sunglasses. If the average transmittance of the ultraviolet rays below 400 nm is not more than 2%, and the wavelength transmittance of more than 400 nm is less than 5%, the lens meets the requirements of UV400. The instrument can measure the UV400 and detect the UV protection of the lens
Real-time dynamic self-calibration
The meter has a real-time dynamic self-calibration function, the transmission meter will be automatically calibrated to 100% transmission or 0% rejection after powering off or when starting a new measurement
Small test aperature
The test aperture of the instrument is 1mm, and the distance between the light source and the detector is 20mm which can measure large thickness materials
LCD screen, fashionable and easy for reading
Large LCD screen display, exquisite and stylish appearance, can be used in exhibitions and so on
Providing various display interfaces to choose
The spectrum transmission meter has two display interfaces in Chinese and English. Four interfaces can be selected:blue light/purple rejection+UV400
Using large LCD screen for easy reading
Real-time dynamic self-calibration function, which automatically calibrates to 100% transmittance after turning on
5V mobile power, easy to connect